Simplex Ethernet Clock Spezifikationen Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
Systems Configured for Typical NEW CONSTRUCTION Applications using Structured Wiring (Cat 3, 5, 5e, or 6)
Basic System Configuration Selection Details (see Note below)
BCS BASIC SYSTEM CONFIGURATION MODULES
5120-9008 5120-9009 5120-9010 5120-9011 5120-9012 5120-9013 5120-9014 5120-9015
5130-9140 24 POINT STATION P.C. BOARD 8 9 10 11 12 13 14 15
5130-9142 12 POINT STATION P.C. BOARD
0 0 0 0 0 0
0 0
5120-9174 VP-6124-P SIX AMP PWR SUPPLY 3 4 4 4 5 5 5 6
5120-9113 NINE POSITION CARD RACK ASSY
2 2 2 2 2 2
2 2
5130-9120 CENTRAL PROCESSOR P.C. BOARD 1 1 1 1 1 1 1 1
5130-9131 POWER CONVERTER P.C. BOARD
1 1 1 1 1 1
1 1
5130-9165 MASTER CLOCK P.C. BOARD 0 0 0 0 0 0 0 0
5120-9335 20 PIN RIBBON CABLE 1 1 1 1 1 1 1 1
5120-9173 QUAD 6 AMP P. S. RACK MT PLATE
1 1 1 2 2 2
2 2
5120-9334 16 PIN RIBBON CABLE 1 1 1 1 1 1 1 1
5120-9332 40 PIN RIBBON CABLE 8 POS
0 0 0 0 0 0
0 0
5120-9333 40 PIN RIBBON CABLE 16 POS 1 1 1 1 1 1 1 1
5120-9336 COMMON POWER CABLE
1 1 1 1 1 1
1 1
748-291 SHIPPING GROUP 1 1 1 1 1 1 1 1
Installation Kit Reference, Ordered Separately and Required, use 5120-90xxK (same as selected above with “K” suffix, see Note below)
BCS FIELD TERMINATION BLOCKS
5120-9923 SCREW TERMINAL BLOCK 0 0 0 0 0 0 0 0
5120-9920 DUAL CONNECTOR PUNCH BLOCK
9 10 11 12 13 14
15 16
5100-9920 SINGLE CONNECTOR PUNCH BLOCK 0 0 0 0 0 0 0 0
BCS FIELD WIRING INTERCONNECT CABLES
5120-9930 25 PR - 5 FT (WALL RACK)
0 0 0 0 0 0
0 0
5120-9931 25 PR - 15 FT (FLOOR OR PIVOTING WALL RACK) 18 20 22 24 26 28 30 32
Compatible Items Ordered Separately; Recommended Quantity Shown if 5100-9865/9867 Wall Rack Assembly is not used
BCS FIELD TERMINATION BACK BOARD
5120-9924 BACK BOARD 2 2 2 2 2 2 2 2
BCS FIELD TERMINATION BLOCK CABINET
5120-9911 BLOCK CABINET 2 2 2 2 2 2 2 2
Note: Items with 0 quantity are compatible and available. If required, order separately.
(continued next page)
7 S5120-0012-17 3/2010
5120 Building Communications System Configuration Reference
Seitenansicht 6
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare